| Primary Measurement Method |
Magnetic induction and/or eddy current |
Pulse-echo ultrasonic measurement |
Mechanical contact measurement |
Ultrasonic pulse-echo, often with corrosion software |
| Typical Applications |
Paint, powder coating, plating, anodizing, and galvanizing inspection |
Metal, plastic, glass, ceramic, and composite thickness measurement |
Machined parts, sheets, foils, tubing, and laboratory dimensional checks |
Pipes, tanks, pressure vessels, structural steel, and corrosion monitoring |
| Typical Measuring Range |
Approximately 0–1,250 μm, depending on probe and substrate |
Approximately 0.8–300 mm, depending on material and transducer |
Commonly 0–25 mm; larger ranges require different frame designs |
Approximately 1–300 mm, with application-specific probes |
| Typical Accuracy to Request |
About ±(1–3% of reading + 1–2 μm), subject to calibration and surface condition |
About ±0.1 mm or ±1% of reading, depending on material and thickness |
Approximately ±2–5 μm for precision models, depending on range and standard |
Approximately ±0.1–0.5 mm, depending on probe frequency and surface condition |
| Compatible Materials |
Ferrous and non-ferrous metals with suitable coating systems |
Metals, plastics, fiberglass, ceramics, and other sound-conductive materials |
Rigid parts that can be securely positioned between the measuring faces |
Steel, stainless steel, aluminum, copper, polymers, and selected composites |
| Relevant Standards |
ISO 2178 for magnetic methods and ISO 2360 for eddy-current methods |
ISO 16809 for ultrasonic thickness measurement |
ISO 3611 for external micrometers and applicable national calibration standards |
ISO 16809, ASTM E797, and applicable corrosion-inspection procedures |
| Calibration Features |
Zero adjustment, certified foils, uncoated substrate plates, and multi-point calibration |
Velocity calibration, zero calibration, reference blocks, and probe delay compensation |
Gauge-block verification, repeatability testing, and controlled measuring force |
Reference blocks, material-velocity calibration, temperature compensation, and probe verification |
| Data and Connectivity |
Internal memory, USB or Bluetooth on selected models, and statistical analysis |
Data logging, USB transfer, Bluetooth or wireless options, and measurement reports |
Digital output may be available; basic models generally provide local readings only |
Inspection maps, trend analysis, alarm limits, reporting software, and database export |
| Probe and Access Options |
Integrated, cable-connected, miniature, angled, and high-temperature probes may be available |
Single-crystal, dual-crystal, delay-line, angle-beam, and high-temperature probes |
Standard anvils, carbide faces, ball contacts, and interchangeable measuring ranges |
Small-diameter probes, dual-element probes, high-temperature wedges, and remote cables |
| Environmental Protection |
Look for an IP rating, commonly IP54 or higher for industrial handheld use |
Rugged housing and sealed keypad are preferred for field inspections |
Protection depends on the design; mechanical models require clean contact surfaces |
Ruggedized housing, sunlight-readable display, and resistance to dust, moisture, and impact |
| Supplier Documents to Request |
Datasheet, calibration certificate, accuracy test results, probe specifications, and user manual |
Material compatibility chart, probe data, calibration procedure, software details, and test report |
Resolution and accuracy data, gauge-block certificate, measuring-force information, and maintenance instructions |
Inspection software documentation, corrosion report sample, calibration records, probe certificates, and service procedure |
| Best Selection Criterion |
Correct combination of coating type, base metal, probe range, and calibration method |
Correct sound velocity, probe frequency, minimum thickness, and surface preparation |
Repeatability, contact geometry, resolution, and traceable dimensional calibration |
Reliable readings on the actual asset, corrosion software, probe access, and after-sales support |